Ethernet Cable Loss Calculator

May 3, 2026

Ethernet Cable Loss Calculator

Estimate signal attenuation, channel margin, and PoE voltage drop for copper Ethernet runs in home labs, offices, APs, and cameras.

🔌Preset Scenarios
Copper loss climbs with frequency, length, and connector count. PoE current adds a second loss path through DC resistance.
⚙Channel Inputs
Sets the advice banner and shows PoE fields when power delivery matters.
Choose the cable family you are actually terminating.
Construction changes connector loss and the small attenuation factor.
Measured in feet for imperial mode.
Each patch cord extends the channel and usually adds extra terminations.
Used for both the reach math and the total channel length.
Count every mated pair from the patch field to the device.
Higher frequencies expose more insertion loss and less headroom.
Used to nudge attenuation and DC resistance.
Thicker copper usually helps both signal loss and PoE voltage drop.
Dense bundles raise heat and slightly reduce margin.
Reserve for aging, bends, and field test variation.
4-pair PoE cuts voltage drop better across longer or warmer channels.
Channel Loss
0.00
dB
Budget Margin
0.00
dB
Max Reach
0.0
m
PoE Voltage Drop
0.00
V

Full Breakdown

💻Equipment and Spec Grid
Cat5e U/UTP
22.0 dB
at 100 MHz
24 AWG, 1 GbE friendly, short margin at high bundle heat.
Cat6 U/UTP
19.0 dB
at 100 MHz
23 AWG, common for 1 GbE and shorter 10 GbE channels.
Cat6A F/UTP
17.0 dB
at 100 MHz
23 AWG, strong 10 GbE headroom at the full 100 m channel.
Cat6A S/FTP
16.8 dB
at 100 MHz
Shielded pair layout helps in noisy racks and tray runs.
Cat7 S/FTP
15.8 dB
at 100 MHz
22 AWG, tighter shielding, and strong EMI tolerance.
Cat7A S/FTP
15.5 dB
at 100 MHz
Extra frequency headroom for specialty short channels.
Cat8 S/FTP
19.0 dB
at 100 MHz
22 AWG, very short 25/40 GbE channels, 30 m channel class.
Outdoor Cat6A
17.5 dB
at 100 MHz
UV or duct rated jacket, useful for tray and riser paths.
📖Reference Tables
Cable 100 MHz Max Freq Typical Run
Cat5e 22.0 dB 100 MHz 100 m
Cat6 19.0 dB 250 MHz 100 m
Cat6A 17.0 dB 500 MHz 100 m
Cat8 19.0 dB 2 GHz 30 m
Construction Atten Factor Connector Loss Notes
Solid horizontal 0.98 0.12 dB Best for in-wall runs
Stranded patch lead 1.06 0.14 dB Flexible but slightly lossier
Shielded plant 0.99 0.13 dB Useful in racks and EMI zones
Preterminated trunk 0.97 0.11 dB Factory assembled harness
Gauge Loop ohm/100m PoE drop @0.6A Notes
22 AWG 10.6 ohm 3.18 V Lowest DC loss of the group
23 AWG 13.3 ohm 4.00 V Common for Cat6 and Cat6A
24 AWG 16.8 ohm 5.04 V Typical patch and Cat5e wire
26 AWG 26.6 ohm 7.98 V Fine for short jumpers only
Scenario Length Category Expected Result
Desktop patch 22 ft Cat6 Easy pass
Ceiling AP 35 m Cat6A Good margin
PoE camera 60 m Cat5e Watch voltage
Outdoor span 90 m Cat6A Borderline but viable
Tip: Use the actual channel, not just the wall run.
Tip: Heavy PoE loads love 4-pair delivery.

This calculator keeps attenuation, connector loss, and PoE voltage drop separate so you can see where Ethernet cable headroom really disappears.

Signal loss are another problem that can occur in Ethernet cables. Signal loss will cause the network speeds to drop for the network, or the device will lose there connection to the network. Signal loss occurs due to an inherent inability of copper Ethernet cables to send high-frequency data signals over long distances.

As the data signal travels along the copper wire, the signal weaken. This loss of signal strength is called attenuation. The longer the cable is, and the more higher the frequency of the signal, the more attenuation will occur.

Why Ethernet Cables Lose Signal and What to Do

High-speed connections like 10 GbE use higher frequencies which lead to more higher levels of attenuation. Another problem with Ethernet cables that contribute to connection issues is Power over Ethernet (PoE). PoE leads to voltage drop in the cable.

The DC resistance in the copper pair causes voltage drops in the cable. The farther the voltage drops in the copper pair, the more significantly the effect of attenuation. A short patch cable may work for the network, but a long cable that is hot to the touch may have signal loss and voltage drops along its length.

The total length of the channel include all the patch cords connected to the Ethernet network. Each patch cord adds length to the channel and attenuation to the data signal. Each mated pair of Ethernet connectors add approximately 0.12 dB of loss to the data signal.

The construction of the Ethernet cable affect signal loss. Solid core fiber is better for long distances than stranded cable. This is because solid core cables are better at transmitting data over long distances than stranded cables.

The temperature of the environment can also affect signal loss. Heat has the ability to increase the resistance of copper by approximately 0.25% for every degree that the copper are heated. Dense bundle of Ethernet cables can become very hot to the touch.

Heat will increase the resistance of the copper in the cable, leading to more voltage drops in PoE connection. Another factor that can affect signal loss is the gauge of the copper wire in the Ethernet cable. Thicker cables with a 22 AWG gauge reduce the DC loop resistance of the cable.

This is beneficial for PoE connection. The problem with 22 AWG wire is that it is more expensive and harder to pull through walls and buildings. 24 AWG Cat5e cable is used for gigabit connections.

However, 24 AWG Cat5e cable may not provide enough bandwidth for 10G connections or for locations that is exposed to high levels of heat. Shielded cables are another option for reducing signal loss in Ethernet cables. Shielded cables reduce the effect of electromagnetic interference (EMI) on the data signal.

These cables lose a small amount of signal to the shield but gain the benefit of noise rejection. When planning an Ethernet network installation, there is a safety margin that must be provided for signal loss. You provide a safety margin to account for bend in the cable, the aging of the cable, and the variance in the quality of testing equipment.

If the signal budget is positive, you have a safe amount of headroom for the signal to travel along the Ethernet cable without loss. A negative signal budget will result in retransmits or link failure for network devices. Outdoor Ethernet cable installations has to take extra care when installing the cable.

Outdoor cables have to have special jackets to resist UV light and weather extreme. You can avoid signal loss when planning an Ethernet installation by calculating the math of copper limits and choosing the specifications of the Ethernet cable.